Galaxy 3 Series Programming Manual
161
5 = Emergencies
This option allows each individual MAX/MicroMAX/MAX
3
unit to be configured to respond to fire zones in a
given set of groups. Upon the opening of a fire zone in one of the groups allocated to the MAX/MicroMAX/
MAX
3
, the MAX/MicroMAX/MAX
3
will trigger the door strike and hold the door open until the system is
reset. All the MAX/MicroMAX/MAX
3
LEDs will light and the buzzer will sound. Closing the fire zone will
have no effect - the MAX/MicroMAX/MAX
3
units are treated as latched outputs and an appropriate level
reset is required, at which point they are immediately reset.
A second group map is allocated to each MAX/MicroMAX/MAX
3
in order to facilitate this function. This
permits the existing door control features to be completely detached from the fire escape features.
The default setting for each MAX/MicroMAX/MAX
3
is all groups selected. Therefore, a system, which is
unchanged from the default will open all MAX/MicroMAX/MAX
3
doors in response to any fire zone activa-
tion.
On selecting the Emergencies option select the groups you want allocated to the MAX/MicroMAX/MAX
3
for escape purposes and accept the programming by pressing the enter key. When a fire zone is activated in
any of the groups programmed, the door controlled by the MAX/MicroMAX/MAX
3
will be opened.
6 = Anti PassBack
This option, when enabled, will prevent more than one use of any particular card at a particular reader within a
given time period.
A forgiveness function is available to clear all or particular antipassback restrictions in force. A manager code
can authorize a forgive function on a particular user in option 42.1 = Codes.User Codes. An engineer code
can authorize a forgive function on a particular reader.
1 = Mode
This option has three settings:
0 = Off No anti passback restriction
1 = Soft Access is never denied but any violations will be recorded in the event log
2 = Hard No access will be granted for a second swipe within the anti passback period,
following a valid swipe.
2 = Timeout (0-60 minutes)
This option specifies the time that the anti passback restriction lasts for.
3 = Forgive
This option allows the engineer to remove all anti passback restrictions for the selected MAX. Use the A>B<
keys to select the reader address the press enter to forgive.
63 - Options (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals