5. Autoset Events
This option programs the times when the selected group is automatically switched On (Autoset) and Off
(Autounset).
On selecting the option, the first 2 times assigned to the timer are displayed (the first time is on the top line, the
second is on the bottom). If no autoset times have been assigned, the keypad displays stars () on the top
line. Press the A key to step through each of the times until the required time is shown on the top line of the
display.
Press the ent key to select the time to be modified. The keypad displays:
the
key deletes the programmed time information;
the A or B keys change the programmed day;
the # key toggles whether the timer switch ON or OFF;
the number keys (0–9) assign the time in the 24 hour format);
Press the ent key to accept the programming and return to the previous menu level.
If a keyswitch zone type (9) is operated twice (i.e. set/unset) during the exit time of an autoset then the autoset
is cancelled.
Operating a keyswitch zone type during the pre-warn period of an autoset will start a Force Set. If you then
activate the switch again (i.e. unset with keyswitch) before the panel sets, the pre-warn continues on the
autoset.
NOTE: When the keyswitch is activated the second time to take panel back into pre-warn, it can be up to
10 seconds before the pre-warn tones at the keypad start up again.
Lockout
Each group can be programmed with 20 Lockout times over a seven day period. These can be combined in
any order of On and Off times as required.
If Lockout has been assigned to a group, the group is locked-out at the Lockout On time or when the group
sets - whichever occurs first. Outputs programmed as Lockout are active while the system is locked out - this
will not always correspond to the times assigned to the Lockout depending on whether the group sets prior to
Lockout On. When a group is locked-out the setting status indicates that it cannot be unset by displaying an
L.
65 - Timers (cont’d)
Day assigned
S indicates autoset feature
ON = autoset
OFF = autounset
Group Selected (A1)
Time assigned
A1SMON ON 17:30A1SMON ON 17:30
A1SMON ON 17:30A1SMON ON 17:30
A1SMON ON 17:30
MON OFF 19:45 MON OFF 19:45
MON OFF 19:45 MON OFF 19:45
MON OFF 19:45
A1LMON ON 17:30A1LMON ON 17:30
A1LMON ON 17:30A1LMON ON 17:30
A1LMON ON 17:30
[<],[>],#,0-9,*[<],[>],#,0-9,*
[<],[>],#,0-9,*[<],[>],#,0-9,*
[<],[>],#,0-9,*
GROUPSGROUPS
GROUPSGROUPS
GROUPS
1234567812345678
1234567812345678
12345678
LLLUULLSLLLUULLS
LLLUULLSLLLUULLS
LLLUULLS

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals