Galaxy 3 Series Programming Manual
B-9
Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
Description Event Description Trigger ID Event
RD Prog, denied RMACCESS+ Zone denied rem. acc ZONE 14.MEN AC 553
RO Relay open BELL FAIL Bell fail zone opened ZONE 16. LOG 150
KEYSWITCH KS NONE 150
LINK+ Link zone opened ZONE 16.LOG 150
LOG+ Log zone opened ZONE 16.LOG 150
LOG DELAY+ Log delay zone opened ZONE 16.LOG 150
NOT USED ZONE 16. LOG 150
SET LOG ZONE 16. LOG 150
CUSTOM A+ Zone opend(Non alarm) ZONE 16.LOG 150
CUSTOM B+ Zone opend(Non alarm) ZONE 16.LOG 150
EXITGUARD+ Exitguard zone opened ZONE 16.LOG 150
PUSH SET Push set zone opened ZONE NONE 150
KSW RESET KS NONE 150
SPARE Spare zone opened ZONE 16. LOG 150
RP Automatic test AUTOTEST Automatic test EVENT ALWAYS TR 602
RR Power Up MEMORY OK Warm start of panel EVENT 13.ELEC ST 305
RS Prog, success RM ACCESS- Zone allowed rem acc ZONE 14.MEN AC 553
REM CALL Remote call complete MOD 14.MEN AC 412
RX Manual test ENG TEST Engineer test USER ALWAYS TR 601
S - Sprinker (Custom SIA - see note 2)
SA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
SB Bypass OMITTED zone ommitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
SJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
SR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
ST Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
SU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
T - Tamper,Test
TA Tamper Alarm TAMPER+ Tamper zone alarm ZONE 9.TAMPER 137
BELL TAMP+ Bell Tamper zone alarm ZONE 9.TAMPER 137
LID TAMP+ Lid Tamper alarm ZONE 9.TAMPER 137
AUX TAMP+ Auxilary Tamper alarm ZONE 9.TAMPER 137
TAMP S/C+ Tamper short circuit ZONE 9.TAMPER 383
TAMP O/C+ Tamper open circuit ZONE 9.TAMPER 383
TAMPER+ Module Tamper MOD 9.TAMPER 145
MISSING+ Missing module alarm MOD 9.TAMPER 145
CV TAMP+ Voltage tamper on zone ZONE 9.TAMPER 383
MAX TAMP+ MAX Module Tamper MOD. 9.TAMPER 145
WALL TAMP Wall tamper zone alarm ZONE 9.TAMPER 137
MASK TAMP ZONE 9.TAMPER 383
ADDED Module Added MOD. 9.TAMPER 531
ENG TAMP+ Engineering Tamper MISC 9.TAMPER None
TE Test End WALK TEST- Walk test finished USER 14.MEN AC 607
Event Codes (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C