Galaxy 3 Series Programming Manual
45
1. Service
This option enables type 3.6 users to control the access mode of the remote servicing package. There are
several options available for increased flexibility and security.
NOTE: This option is only available when the Manager Authorize option has been enabled (refer to
option 56.1.12 = COMMUNICATIONS. Telecom.Remote Access). If the option is not
enabled, the keypad displays NO ACCESS - OPTION DISABLED.
0 = INT Telecoms
This option selects the on-board telecoms as the communication device.
0 = Direct Access
On selecting this option, a 40 minute access period is enabled on the Galaxy panel; remote servicing software
can directly access the system during this period. Once access to the panel has been gained, it can be main-
tained indefinitely; there is no maximum duration. On terminating the remote servicing connection to the panel,
the access period remains valid for an additional 15 minutes.
1 – 5 = Call Back 1 – 5
A maximum of five numbers can be preprogrammed by the engineer (refer to option 56.1.12 =
COMMUNICATIONS.Telecom.Remote Access). On selecting one of the numbers (1 – 5) followed by
the ent key, the Galaxy panel dials out to the preprogrammed telephone number associated with the Call
Back number.
If the number selected does not have a preprogrammed telephone number, the system prompts for a number 1
to be entered. Enter the required telephone number and press the ent key; the panel then dials out to the
telephone number entered.
NOTE: The PC that the panel is dialling to must have remote servicing software running in the Waiting for
Call-Back mode.
1 = ISDN
0 = Direct Access
See INT Telecoms description
1 – 5 = Call Back 1 – 5
See INT Telecoms description (except menu option 56.3.09 replaces 56.1.12).
2 = Ethernet
0 = Direct Access
See INT Telecoms description
1 – 5 = Call Back 1 – 5
See INT Telecoms description (except menu option 56.4.03 replaces 56.1.12).
47 - Remote Access (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals