EasyManuals Logo

Honeywell Galaxy 3-48C Programming Manual

Honeywell Galaxy 3-48C
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Galaxy 3 Series Programming Manual
48
4 = Conn. Retry
If the attempt to initiate a remote servicing call fails, the panel can be programmed do repeat dial attempts.
There are three further options:
1 = Retry Interval
The dial attempts can be programmed to occur from 0-60 minutes. Setting the value to 0 disables the feature
The default setting is 30 minutes.
2 = Retry Duration
The length of time that the panel tries to do a remote servicing call can be programmed from 0-24 hours.
setting the value to 0 disables the feature. The default setting is 6 hours.
3 = Redial Mode
In the event of a remote servicing session terminating unexpectedly, the panel enters one of the three program-
mable modes that follow.
0 = Off
The panel does not try to re-establish a connection.
1 = Retry
The panel initiates a remote servicing call to re-establish a connection. The retries will be as per option
47.4.4.1 (Retry Interval) and 47.4.4.2 (Retry Duration).
2 = Direct
The panel access mode changes to allow direct access for 30 minutes. This mode operates as per
option 47.1=Service when Direct Access is selected.
5 = Control Upload
This option controls whether a connection is established when only engineer or user programming data is
uploaded. This feature has three options.
1 = Eng Prog
Only initiates a connection when engineering programming has been modified.
2 = User Prog
Only initiates a connection when user programming has been modified.
3 = Either
Initiates a connection when either engineering or user programming has been modified.
6 = Remote Maint
This option controls the mode for automatically initiating communications for remote routine inspection and
maintenance. The panel uploads only the most recent information available from 61=Diagnostics. No other
panel programming is uploaded. There are two sub-options that control this:
47 - Remote Access (contd)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals