Galaxy 3 Series Programming Manual
68
65 = Reset levels
This parameter determines the type of user that can reset specific fault types. The default values are shown in
the table below.
Table 13. User Type Reset Level
51 - Parameters (cont’d)
62 = Lockout
This parameter prevents code guessing on the Galaxy system.
1=Lockout
This parameter determines the number of invalid code attempts, which can be tried before keypad lockout
occurs. Keypad lockout prevents any entry via all keypads associated to the groups assigned to the keypad
where the invalid attempts were made. The lockout lasts for 90 seconds. Each subsequent invalid attempt to
cause a further 90 second lockout to occur. Entry of a valid code will reset the lockout counter. Lockout can
be programmed between 0 and 10. Default is 6.
2=Tamper
This parameter determines the number of invalid code attempts, which can be tried before system tamper
occurs. Lockout tamper can be programmed between 0 and 21. Default is 15.
63 = Banner Alerts
This parameter determines whether system alerts are displayed on the Galaxy keypad banner. If enabled
system events will be indicated on the display. The default value for this parameter is disabled.
64 = Set Override
This parameter determines the type of user that can override specific fault events to set the system. The default
values are shown in the table below.
Table 12. User Type Override Level
A different value can be programmed for each group.
epyTtluaF
epyTresU
leveLedirrevO
metsyS1.2
repmaT6.3
AP1.2
liaFeniL6.3
tluaFlareneG1.2
liafrewoP1.2
NOTE: This parameter affects and is affected by parameters 51.6 (System Reset), 51.7 (Tamper Reset) and
51.22 (PA Reset). If the parameter reset level is changed at 51.65 then this change is reflected at
51.6, 51.7 and 51.22.
Fault Type
User Type
Reset Level
System 3.6
Tamper 3.7
PA 3.6
Line Fail 3.7
General Fault 3.7
Power Fail 3.6

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals