03=Pre-alarm 1=No. of photos. (1 to 10, the default is 4). 2=Interval defines the
time delay between each photo (200 to 1000 ms). The setting range is 0
to 8.
04=Post Alarm 1=No. of photos. (1 to 10). 2=Interval defines the time delay between
each photo (200 to 1000 ms). The setting range is 0 to 8.
05=Night Illum. Defines if the Infrared Lighting is switched on in darkness after an
alarm is detected (1=On and 0=Off).
06=Resolution Set the resolution (0=Low, 1=High). Low resolution is 320 x 176
pixels and high resolution is 640 x 352 pixels.
07=Colour If required, set the colour to colour (0=B/W mode (default),
1=Colour mode).
08=Alarm Limit This limits the number of pictures taken for each alarm type by each
camera. The range is 0 to 10 and the default setting is 3.
Simple Set [51.80]
Use this option to enable the panel to be set and unset without the need to press ent.
Ou
tput Option [51.81]
When the Output Option plug-in board is fitted (see Figure 3 PCB layout and connection),
use this option to define which mode of operation the Option Module will follow. The
setting chosen must match the jumper switches settings on the module. There are two
settings:
1=Relay Works as a single-pole 2-way relay extension of output 3.
2=Siren Works as a monitored 2-wire siren circuit.
Output 3 Mode [51.82]
Use this option to set the mode of output 3 on the control panel (output 99 in menu 53). The
output can be configured in two modes
1=Speaker Works as a loud speaker driver for a 16 ohm speaker
2=DC Output Works as a normal, programmable, switched output
If mode 1 is selected you can set the volume of the loudspeaker from 0-31
Use this option to set the horn volume. The range is 0 to 30 and the default setting is 15.
Common Siren [51.83]
Use this option to enable a user in a group, which shares a siren with other groups, to silence
the siren after an alarm has occurred in another group. Normally the siren can only be
silenced by a user in the group with the alarm.
Silencing the siren in this situation does not reset the alarm or delete any information about
the alarm. Users in the group with the alarm can still see the alarm information.
0=Disabled, 1=Enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals