Galaxy Flex Installer Manual Program Outputs [53]
131
40 Fail Set (Latch)
Fail Set is activated if the system (or assigned groups) fails to set within the time assigned in
35=Fail to Set (refer to Parameters [51]).
41 Duress (Latch)
This function is activated by any code assigned as a Duress Code using Codes [42]. The
output is not subject to the Re-arm parameter. It latches on and remains active until a valid
code (type 2 or above) is entered.
42 Illegal Code (Latch)
This output is activated 60 seconds after a single Dual Code entry or a code entry without
the Timer A and/or Timer B times assigned to it (refer to Schedule [42.1.4]).
44 Abort (Latch)
This output is activated after a valid code entry during the Abort period on system entry.
45 Unset (Pulse)
This output is activated each time the system (or group) is unset. The default output mode
attribute is programmed as pulse, for two seconds. This can be used to activate a buzzer to
notify a user that the system has been unset, when using an RF fob.
46 Set Late (Latch)
This output is activated if the system has not been set by the programmed Monitor time
(refer to Status [65.3.1]).
47 U/S Early (Latch)
This output is activated if the system has been unset before the programmed Monitor time
(refer to Status [65.3.1]).
48 Prewarn (Reflex)
This output is active during the programmed pre-warning period of the autoset function. The
mode is Reflex. The Prewarn emits a constant tone if the auto setting of the system can be
extended. If an extension is not possible, Prewarn outputs pulses.
49 Autoset (Reflex)
This output is activated when the system has been set by the autoset function (refer to
Autoset [65.3]). The default Output Mode attribute is programmed as Reflex, therefore the
output remains active until the system unsets.
Note: The Set is also activated when the system autosets.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals