Communications [56] Galaxy Flex Installer Manual
148
Module config [56.3]
This section allows alterations to be made to the characteristics of the different
communications modules.
 1 = PSTN
 1 = Line Fail (0 = Disabled, 1 = Enabled)
 2 = No. of rings (04 (1-20))
 3 = SMS (1 = Centre ID, 2 = Protocol, 3 = Password)
 2 = GSM/GPRS
 1 = GSM
 1 = Line Fail (0 = Disabled, 1 = Enabled)
 2 = GPRS
 1 = Encryption
 1 = Alarm Report (0 = Disabled, 1 = Enabled)
 2 = SIA Control (0 = Disabled, 1 = Enabled)
 3 = IP Check (0 = Disabled, 1 = Enabled)
 2 = Connection (Timeout, the default is 15 mins)
 3 = Line Fail (0 = Disabled, 1 = Enabled)
 4 = IP Check Cfg (1 = Intervals, 2 = Acknowledge)
 3 = Network 1
 1 = PLMN
 2 = APN
 3 = Login
 4 = Password
 5 = Centre No.
 6 = Connection (1 = Continuous, 2 = Timeout)
 4 = Network 2
Same sub-options as Network 1 (without SIM PIN)
 5 = Network 3
 6 = SIM PIN
 7 = SMS Receipt (0 = Disabled, 1 = Enabled)
 3 = Ethernet
 1 = DHCP (0 = Disabled, 1 = Enabled)
 2 = IP Address
 3 = Gateway IP
 4 = Network Mask
 5 = Encrypt
 1 = Alarm Report (0 = Disabled, 1 = Enabled)
 2 = SIA Control (0 = Disabled, 1 = Enabled)
 3 = IP Check (0 = Disabled, 1 = Enabled)
 6 = Line Fail (0 = Disabled, 1 = Enabled)
 7 = IP Check Cfg (1 = Intervals, 2 = Acknowledge)