Engineer Test [56.7]
Use this option to verify that an ARC is receiving transmissions via a particular
communications path (setup in 56.1.1). You can also test all Receivers as once (select
10=All receivers).
On selecting the option this warning message is displayed on the keypad:
WARNING!!! ent=SEND MESSAGE
Press ent to send the engineer test.
The test attempts to transmit once for each selection of the option. If the test is not
successfully transmitted, the communicator does not attempt to resend. An unsuccessful
transmission is not counted as a FAIL TO COMMUNICATE.
Note: Activation of an engineer test will send a test signal via all communication modules.