Timers [65] Galaxy Flex Installer Manual
178
Use the A or B keys to select the required day or days and press ent to accept the
programming and return to the previous menu level:
1=MON; 2=TUE; 3=WED; 4=THU; 5=FRI
Timer Outputs [65.2]
Once the times have been programmed and the Status is set to 1=On, the Timer-A or Timer-
B outputs types 29 and 30 are activated at the On times and deactivated at the Off times
programmed in Weekly Schedule [65.1].
Autoset [65.3]
Each group can be programmed with up to 42 Autoset events over a 7 day period. These can
be combined in any order of On and Off times as required.
When the system has been set by the Autoset function, outputs programmed as Autoset are
activated (refer to Program Outputs [53]); the Set outputs are also activated.
Programming Autoset
If groups are enabled (refer to O
ptions [63]) the keypads prompts for the group that the
autoset time is to be allocated to. Press A or B to step through the groups until the required
number is displayed and press ent.
Account Group Autosetting
Account Group autosetting is allowed. This means that several groups can be bound together
into one account group and, instead of a sending a normal CA (closed automatically) event,
the panel sends a CL (closed late) event.
Refer to Account No [56.1.2.2.2].
There are five stages to programming the Autoset function:
Autoset Status [65.3.1]
0=Off (default)
1=On
2=Monitor If selected, the setting and unsetting of the group is monitored:
If not set manually before the On time, then the Set Late output is activated.
If unset before the Off time, then the Unset Early output is activated.
Prewarning [65.3.2]
1=Period 0 – 50 minutes (default 30 minutes)
2=Audible (this can be turned ON or OFF)
Use this option to set the warning period given to users prior to the system autosetting.
Outputs programmed as Pre-warning activate during the pre-warning period. The output
normally emits a constant tone, however if an extension is not possible, then a pulsed tone is