EasyManuals Logo

Honeywell Galaxy Flex V3 Series User Manual

Honeywell Galaxy Flex V3 Series
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #206 background imageLoading...
Page #206 background image
Appendix B: SIA & contact ID event codes Galaxy Flex Installer Manual
206
Ev SIA Event Log Log Event Ev Type Trigger Contact
Description Event Description ID Event
RX Manual test ENG TEST Engineer test USER ALWAYS TR 601
User test USER TEST User communications test USER ALWAYS TR 601
User test pass USER TEST P User test has passed USER ALWAYS TR 601
User test fail USER TEST F User test has failed USER ALWAYS TR 601
S - Sprinkler (Custom SIA - see note 2)
SA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
SB Bypass OMITTED zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
SJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
SR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
ST Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
SU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
T - Tamper, Test
TA Tamper Alarm TAMPER+ Tamper zone alarm ZONE 9.TAMPER 137
BELL TAMP+ Bell Tamper zone alarm ZONE 9.TAMPER 137
LID TAMP+ Lid Tamper alarm ZONE 9.TAMPER 137
AUX TAMP+ Auxiliary Tamper alarm ZONE 9.TAMPER 137
TAMP S/C+ Tamper short circuit ZONE 9.TAMPER 383
TAMP O/C+ Tamper open circuit ZONE 9.TAMPER 383
TAMPER+ Module Tamper MOD 9.TAMPER 145
MISSING+ Missing module alarm MOD 9.TAMPER 145
CV TAMP+ Voltage tamper on zone ZONE 9.TAMPER 383
MAX TAMP+ MAX Module Tamper MOD. 9.TAMPER 145
WALL TAMP Wall tamper zone alarm ZONE 9.TAMPER 137
MASK TAMP ZONE 9.TAMPER 383
DCM EVENT Invalid Card Tamper alarm MOD. 9.TAMPER None
ADDED Module Added MOD. 9.TAMPER 531
ENG TAMP+ Engineering Tamper MISC 9.TAMPER None
TE Test End WALK TEST- Walk test finished USER 14.MEN AC 607
TR Tamper Restor TAMPER- Tamper zone restored ZONE 9.TAMPER 137
18.ZN RESTO
BELL TAMP- Bell Tamper zone rest. ZONE 9.TAMPER 137
18.ZN RESTO
LID TAMP- Lid Tamper restored ZONE 9.TAMPER 137
18.ZN RESTO
AUX TAMP- Auxiliary Tamper rest. ZONE 9.TAMPER 137
18.ZN RESTO
TAMP S/C- Tamper s/circuit rest. ZONE 9.TAMPER 383
18.ZN RESTO
TAMP O/C- Tamper o/circuit rest. ZONE 9.TAMPER 383
18.ZN RESTO
TAMPER- Module Tamper rest. MOD 9.TAMPER 145
18.ZN RESTO
MISSING- Missing module rest. MOD 9.TAMPER 145
18.ZN RESTO
CV TAMP- Voltage tamper rest. ZONE 9.TAMPER 383
18.ZN RESTO
MAX TAMP- MAX Module Tamp rest MOD. 9.TAMPER 145
18.ZN RESTO
ENG TAMP- Engineer Tamper MISC 9.TAMPER None
18.ZN RESTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals