Connecting the Audio Interface Module to the PSTN
Connect the module to the panel PCB as shown below:
Control Panel PCB
PHONE
LINE
A
B
AB
Audio Interface PCB
Extension Phone
Incoming
PSTN Line
30 metres max.
from panel to
Audio Interface
PHONE LINE
A BAB
Figure 16 Audio Interface connected to PSTN
Connecting microphones and speakers
The audio channels will work with most line-level audio equipment. Use microphones with
a
pre-amplifier that delivers audio at line-level (3 V peak to peak). The module can transmit
audio to speakers that accept line-level signals. Please read any instructions that come with
your microphone regarding the adjustment of sensitivity. The module can be used with the
following Honeywell audio devices:
TP800/TP2-800GY Speaker and microphone unit
IS215TCE-MIC PIR detector with built-in microphone
DT7450-MIC Dual Tech detector with built-in microphone
TP800/TP2-800GY connection
Speaker and microphone connections
Audio Interface TP800/TP2-800GY
GND VS-*
+4.5 V VS+
CMD CMD
SPK RML
MIC ECOUT
TMP AP
AP*
* Connect these two points together to complete the tamper

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals