Galaxy Flex Installer Manual Remote Access [47]
79
Auto Service Timers Sync Schedule [47.4.2.3]
Use this option to program the panel to automatically connect to the remote servicing
application and upload the latest panel programming during the off-peak window. The
period of time between connections can be set from 0 to 365 days. The default setting is 0,
which disables the option.
The off-peak time window is programmed in menus 47.4.2.1 and 47.4.2.2.
Auto Service Timers Schedule Reset Off [47.4.2.4.0]
The panel never initiates a remote servicing connection. This is the default setting.
Auto Service Timers Schedule Reset Auto [47.4.2.4.1]
Use this option to reset the Sync Schedule timer after an automated connection.
Auto Service Timers Schedule Reset Manual [47.4.2.4.2]
Use this option to reset the Sync Schedule timer, after a copy of site data whether done
automatically or manually.
Auto Service Terminate Idle [47.4.3]
Use this option to program a timeout period that terminates a remote connection after the
programmed period of activity. The range is 0 to 60 minutes, and the default timeout period
is 10 minutes. After termination the panel records in the event log the message REM
ABORT to indicate that the connection was unexpectedly terminated.
Conn. Retry Interval [47.4.4.1]
Use this option to program the dial attempts from 0 to 60 minutes. The default setting is 30
minutes, and 0 disables the feature.
Conn. Retry Duration [47.4.4.2]
Use this option to set the time the panel tries to make a remote servicing call. The range is 0
to 24 hours. The default setting is 6 hours, and 0 disables the feature.
Conn. Retry Redial Mode Off [47.4.4.3.0]
Use this option to disable the panel from trying to re-establish a connection.
Conn. Retry Redial Mode Retry [47.4.4.3.1]
The panel initiates a remote servicing call to re-establish a connection. The retry is
controlled by option Retry Interval [47.4.4.1] and Retry Duration [47.4.4.2].
Conn. Retry Redial Mode Direct [47.4.4.3.2]
The panel access mode changes to allow direct access for 30 minutes. This mode operates
when Direct Access is selected in the Service [47.1] option.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals