EasyManua.ls Logo

Honeywell HON 673 - Page 64

Honeywell HON 673
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Storage, removal, and disposal
HON 380 gas pressure regulator with HON 673/674 controller 64
9 Storage, removal, and disposal
Topic Page
Storing the device 64
Disassembling the device 65
Disposing of the device 66
9.1 Storing the device
Observe the following rules:
Do not store the device outdoors.
Store the device in a dry and dust-free environment on a flat surface.
Do not expose the device to any aggressive media, ozone or ionizing radia-
tion or to direct heat sources.
Storage conditions:
Temperature: 0 °C to 25 °C (32 °F to 77 °F)
Relative humidity: < 55 %.
Avoid mechanical vibrations.
Storage periods:
When storing the device for up to one year:
Store the device in its original packaging and in the same condition
it was delivered. All protective caps of the device must remain in
place.
When storing the device for more than one year (e.g., as a backup
device):
Store the device in its original packaging and in the same condition
it was delivered and check it annually for damage and soiling.
Consider the storage period in the maintenance cycles.
Note: Please also observe any storage information provided on the packaging.
The following rules apply to the storage of spare parts:
Apply an appropriate protective agent to assemblies at risk of corrosion.
If stored correctly, O-rings and gaskets should not be kept longer than
7 years.
Store the spare parts in the original package until they are used.
Contents
Storage of the
packing units
Storage of spare parts

Related product manuals