24
Operating Manual IK3 Operating Unit with Keypad
8.3 Hold-up alarm
A can be triggered via the operating unit keypad with a hold-up code.
The is identical with the PIN with the exception of the last digit.
(For other digits, see Chapter 9 "Appendix").
: PIN 456789
Hold-up code 45678 =
The hold-up code is thus
A possible tens digit is
A hold-up alarm is triggered irrespective of whether the system is in an armed or disarmed state.
Even if the operating unit is used for AC functions, a hold-up alarm can be triggered.
hold-up alarm
hold-up code A 5 is added to the
last digit.
9+5 4
456784
not carried over.
Example
Note: If a hold-up alarm is triggered, the "Alarm" indicator does not light up!
Acknowledgement:
Authorization
Hold-up alarm
is triggered
No authorization
Disarmed
(yellow)
Ready
(green)
Positive acknowledg. Negative acknowledg.
Optical
Action
Hold-up alarm is
triggerednot
5 sec.
Dis-
armed
Armed
Acoustical
(signal)
2 sec.
Only when disarming
Trigger hold-up alarm
Trigger hold-up alarm
Trigger hold-up alarm
Enter the hold-up code, acknowledgement follows
Activate the “disarm” key
Hold the IK data carrier in the reading range
(only if required for disarming)
Enter the hold-up code, acknowledgement follows
The system is disarmed
Hold the IK data carrier in the reading range
(only if required for AC function)
Enter the hold-up code, acknowledgement follows
Door lock release follows
The (PIN + IK-D or IK-D + PIN) is .
with disarming
with AC door lock release
sequence irrelevantNote:
0....9
0....9
IK-D
0....9
IK-D