Operating Manual IK3 Operating Unit with Keypad
8.6 Control functions
The control and switching functions can be executed via the operating unit keypad. The desired func-
tions are defined via the programming of the central control unit / evalutiation unit and activated via
the function number entered at the operating unit.
How to call the control functions is defined in the programming of the central control unit/EU.
Positive acknowledgement after action is completed ("Ready" indicator, signal)
If there is or the entered , a
follows!
no authorization function number does not exist negative acknowl-
edgement
Call functions:
1. Activate key (Quick)
ATTENTION: Only 1 macro
2. Only IK data carrier
3. Only PIN
4. With IK data carrier and PIN
With PIN and IK data carrier
Activate the "F" function key
Confirm with "OK", acknowledgement follows
is possible
Activate the "F" key
Enter the function number
Confirm with "OK”
Hold the IK data carrier in the reading range,
acknowledgement follows
Activate the "F" key
Enter the function number
Confirm with "OK"
Enter PIN, acknowledgement follows
Activate the "F" key
Enter the function number
Confirm with "OK"
Hold the IK data carrier in the reading range,
"Ready” flashes 1x
Enter PIN, acknowledgement follows
Activate the "F" key
Enter the function number
Confirm with "OK"
Enter PIN, "Ready" flashes 1x
Hold the IK data carrier in the reading range,
acknowledgement follows
F
0....9
F
0....9
F
0....9
0....9
F
0....9
0....9
F
0....9
IK-D
IK-D
IK-D
3
3
3
3
3
or