Automatic burner control unit IFD 258
Technical Information · GB
6
Edition 03.12l
For directly ignited burners of unlimited capacity in continuous
operation pursuant to EN 746-2
Immediate fault lock-out or restart following flame failure
available as a switchable function
Flame control with UV sensor or ionization sensor
Space-saving installation on site with IFD 258..I with integrated
ignition
Display for program status and flame signal intensity
AGA

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Honeywell krom schroeder IFD 258-5/1W and is the answer not in the manual?

Honeywell krom schroeder IFD 258-5/1W Specifications

General IconGeneral
BrandHoneywell
ModelIFD 258-5/1W
Frequency50/60 Hz
Field of ViewNot applicable
CategoryControl Unit
Detection PrincipleFlame detection
Output SignalRelay output
Contact Rating5 A at 250 V AC
Operating Temperature Range-20 °C to +60 °C
Weight0.3 kg
CertificationsCE
Power Consumption5 VA
Response Time1 second

Summary

Application

Certification

Function

Connection diagrams

Illustrates wiring diagrams for IFD 258 and IFD 258..I units.

Program sequence

Details the step-by-step operational sequence during start-up and operation.

Program status and fault messages

Explains how to interpret program status codes and fault messages.

Parameters

Flame control

Details parameters related to flame detection and control.

Behaviour during start-up

Describes the unit's operational behavior during the burner start-up phase.

Behaviour during operation

Details the unit's operational behavior during normal burner operation.

Selection

Selection table

Presents a table for selecting unit variants based on type codes.

Project planning information

Emergency stop in the event of fire or electric shock

Details how to implement emergency stop for fire or electric shock risks.

Emergency stop triggered by safety interlock

Describes emergency stop activation via safety interlock signals.

Behaviour in the event of flame failure

Explains restart or fault lock-out procedures after flame failure.

Wiring

Provides instructions for correct wiring of the burner control unit.

Flame control

Describes flame detection methods using ionization or UV sensors.

Commissioning

Details the behavior of the IFD unit after voltage removal and reconnection.

Technical data

Installation

Provides guidelines and details for installing the burner control unit.

Legend

Glossary

Fault lock-out

Explains the procedure for fault lock-out and resetting.

Related product manuals