EasyManua.ls Logo

Honeywell Pallet Accuglide ZoneFlex Accumulation Conveyor - 3.5 Maintenance Inspections; 3.5.1 Drive Chain

Honeywell Pallet Accuglide ZoneFlex Accumulation Conveyor
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20 Pallet Accuglide ZoneFlex Accumulation Conveyor | Maintenance Manual | 29334206
February 14, 2018
Preventive Maintenance
Initial Start-Up and Run-In Period
Date:
Checked
by:
Changes/Repair
made:
Perform the following checks during the initial
start-up and run-in period. Perform the checks on
a daily basis for the first week then weekly for the
next three (3) weeks
Listen for unusual noises or excessive vibrations.
Observe the general condition of all floor supports
or hangers and other mounting hardware.
Check that the chain is tensioned.
Observe chain-to-sprocket alignment to ensure
the chain is properly aligned with the sprocket
teeth.
Check that the filter/regulator pressure is set at 25
psi.
Listen for leaks around pneumatic connections.
Check the chain for unusual signs of wear or
damage.
Check for mis-alignment at all sprockets in the
drive and idler sections.
Check the pad to ensure it is properly seated on
the chain pins.
Observe the pad at the drive/idler sprockets to
ensure the carrier rollers are not contacting the
driver pad on the return side.
Check the condition of all driver pad splices.
Verify the pad is free of dirt or oil that may reduce
friction drive force.
Check the oil level in the oiler reservoir.
Check the chain for insufficient or over lubrication.
Check that the oiler air regulator is set at 12 psi.

Table of Contents