Pallet Accuglide ZoneFlex Accumulation Conveyor | Maintenance Manual | 29334206 93
February 14, 2018
Table 7-1 Trouleshooting Problem and Solution
Electrical power shut off or
control circuit NOT
energized.
Check that the system
control panel(s) are
energized. Check the motor
disconnect switch is on.
Check that emergency stop
devices are not activated.
System control devices
(photo-cells, limit switches,
etc.) out of adjustment or
defective.
Check conveyor drive
system and overload sizing
before resetting.
Photo-cell or other control
device(s) actuated or
defective.
Check for obstruction of
control device: remove
obstruction or replace
control device if defective.
Correct conditions and
reset in accordance with
control logic.
Power or component failure
at system control center.
Consult vendor data for
corrective action.
Check conveyor drive
system and overload sizing
before resetting.
Gearmotor unusually
noisy
Mounting bolts are loose.
Tighten the mounting bolts.
Insufficient lubrication.
Check oil level and add if
necessary.
Conveyor rollers not
turning or have
insufficient drive
Remove obstruction and
inspect roller for damage.
Adjust the photo-eye as
required.
Dirty rollers and/or urethane
drive pad.
Clean rolls and/or driver
thoroughly using (409) or
similar household cleaner.
Check the regulator setting.
Check for air leaks
Check the driver pad for
wear, and replace if
needed.