Calibration Handbook
159Calibration Kits and Equipment
Calibration Kits, Calibration Components, and Calibration Gas
EC-F2
11252-L9
For 17L/34L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10687-L9), Carrying Case
11253-L9
For 29L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
11337-L9
For 58L/103L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
EC-F3
11252-L9
For 17L/34L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10687-L9), Carrying Case
11253-L9
For 29L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
11337-L9
For 58L/103L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
EC-F9
11252-L9
For 17L/34L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10687-L9), Carrying Case
11253-L9
For 29L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
11337-L9
For 58L/103L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
IR-F9
11252-L9
For 17L/34L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10687-L9), Carrying Case
11253-L9
For 29L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
11337-L9
For 58L/103L Cylinders Includes: Calibration Adapter w/Tubing and Tee (10244),
Regulator (1LPM - 10597-L9), Carrying Case
E
3
Point
1309K0002
For 17L/34L Cylinders Includes: Tubing (M-508808 - 1/8 ID x 1/4 OD x 6ft),
Polyurethane Tubing (M-502730 - 4mm ID x 6mm OD), Magnet for GasPoint II
(M-502499), Calibration Adapter for IAQPoint (M-512438), Calibration Port for
201T/201M/301M/GasPoint II (M-501080), Calibration Adapter for E
3
Point and
301W (131635-L3), Calibration Adapter for ToxyPoint (M-505490), Calibration
Adapter for EC-F9 (M-507527), Regulator (0.1LPM - M-505425), Regulator
(0.5LPM - M-502877), Carrying case (M-501056)
1309K0004
For 58L/103L Cylinders Includes: Tubing (M-508808 - 1/8 ID x 1/4 OD x 6ft),
Polyurethane Tubing (M-502730 - 4mm ID x 6mm OD), Magnet for GasPoint II
(M-502499), Calibration Adapter for IAQPoint (M-512438), Calibration Port for
201T/201M/301M/GasPoint II (M-501080), Calibration Adapter for E
3
Point and
301W (131635-L3), Calibration Adapter for ToxyPoint (M-505490), Calibration
Adapter for EC-F9 (M-507527), Regulator (0.1LPM - M-502874), Regulator
(0.5LPM - M-502875), Carrying case (M-501057)