VisionPRO TM 8000 Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (Continued)
Installer Setup
Number Installer Setup Name Settings Notes
0650 Extended Fan OnTime 0--no extended fan operation after call for heat ends Not shown iffan operation
Heat 90-- fan operation is extended 90 seconds after call for is set to fossil fuel or in
heat ends. Cool Only Systems
0660 Extended Fan On Time 0--no extended fan operation after call for cool ends Not shown in Heat Only
Cool 90--fan operation is extended 90 seconds after call for Systems.
cool ends.
0670 Keypad Lockout
0680
0690
O7OO
0--unlocked keypad
l--partially locked keypad
2--fully locked keypad
Temperature Control in
Heat
Temperature Control in
Cool
Temperature Display
Offset
l--less aggressive temperature control (could cause
temperature undershoot)
2--Standard temperature control in heating (factory
setting)
3--more aggressive temperature control (could cause
temperature overshoot)
l--less aggressive temperature control (could cause
temperature undershoot)
2--Standard temperature control in cooling
(factory setting)
3--more aggressive temperature control (could cause
temperature overshoot)
-3 --°F (-1.5°C)
-2 --°F (-1°C)
-1 --°F (-.5°C)
0 --°F (0. °C) -- (no difference in displayed temperature
and actual room temperature )
I --°F (.5°C)
2--°F (1°C
3 --°F (1.5°C)
Unlocked--all functions
are available.
Partially locked--only
temperature up and down
keys and ability to enter
and modify Installer Setup
mode are available.
Fully locked--only ability
to enter and modify
installer Setup mode are
available.
Applies to recovery ramp
and use of auxiliary heat
during recovery.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.
Applies to recovery ramp.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.
0710 Reset Thermostat 0--no thermostat reset. Only calendar settings
l--resets all Installer Setup Options to default values and and time are retained.
resets schedule to default setting.