VisionPRO TM 8000 Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (Continued)
Installer Setup
Number
0360
O38O
0500
0510
0520
0530
0540
Installer Setup Name
Heat Pump Auxiliary
Lockout
Indoor Dehumidification
Control
Furnace Change
Reminder
Humidifier Pad
Replacement Reminder
UV Lamp Replacement
Reminder
Adaptive Intelligent
Recovery TM
Number of Periods
Settings
0--no auxiliary heat lockout.
40°F (4.5°C)
45°F (7°C)
50°F (10°C)
55°F (13°C)
60°F (15.5°C)
0--No indoor dehumidification control.
l--Dehumidification control activated.
0--furnace filter reminder off
1--10 run time days
2--30 run time days
3--60 run time days
4--90 run time days
5--120 run time days
6--365 run time days
0--humidifier pad replacement reminder off
1--90 calendar days
2--180 calendar days
3--365 calendar days
0--UV lamp replacement reminder off
1--365 calendar days
lmAdaptive Intelligent Recovery TM control is activated
(system starts early so setpoint is reached by start of
program period).
0--Conventional Recovery (system starts recovery at
programmed time)
2--two periods available (Wake and Sleep)
4 four periods available (Wake, Leave, Return and
Sleep)
Notes
Shown if electric is
chosen for backup heat
source and outdoor
temperature sensor for
control is selected. (See
Advanced Features
section for more
information.)
Available on select
models.
If dehumidification control
is activated and auto-
changeover is selected in
Installer Setup Number
0300, the deadband
minimum is defaulted to
5°F
(3°C) in Number
0310.
Run time based on call for
fan.
Not shown if non-
programmable is
selected. 2 or 4 applies to
all days of the week.
0580 Minimum Compressor 5--five-minute compressor off-time setting (factory --
Off Time setting)
0, 2, 3, 4--other compressor off-time settings
0600 Heat Temperature 40-90--temperature range (1 °F increments) of heating Shown in 1t2 °C.
Range Stop setpoint.
0610 Cool Temperature 50-99--temperature range (I°F increments) of cooling Shown in 1/2 °C.
Range Stop setpoint.
0640 Clock Format 12--12 hour clock (factory setting)
24--24 hour clock