5. Tap “Networking” to access to the networking page, and tap “Networking” at the bottom left corner to
perform parallel operation. The inverter connected to the DTS is the master, and the others are slaves.
After the slaves are connected to the master through a communication cable, they can communicate with
the DTS. Note that a single DTS can only communicate with up to 10 inverters. If you want to change the
master, tap “unbind” to change the master or stop parallel operation.
6. Tap “Battery Smart Control” to set the EMS mode, including Self-Consumption Mode, Economical Mode,
Full Backup Mode, Pure Off-Grid Mode, Force Charge Mode, Force Discharge Mode, Peak Shaving Mode,
and Time of Use Mode.
★
Self-consumption Mode
In the daytime, solar energy supports the loads firstly, and surplus energy is stored in the battery. When
the battery is fully charged or reaches the maximum charge power, the surplus energy is fed into grid (or
limited if required). At night, the battery discharges for the loads firstly, and the grid will supply the loads
once the battery power is not enough. In this mode, battery cannot be charged from grid at night.
The self-consumption mode can reduce the use of grid power. Solar energy is preferentially supplied to the
load, charged to the battery, and fed into the grid last. Users can set the reserve capacity within a certain
range (a small amount of power can be reserved due to infrequent power outages), and then tap “Save”.