Page #134 background imageLoading...
Page #134 background image
2
Set
the
Synthesizer
output
level
to
0
dBm
at
200
Hz.
3
Adjust
the
Synthesizer
output
level
until
the
reading
on
the
AC
Voltmeter
is
between
1.5420
V
and
1.5491
V
4
Connect
the
600i2
resistor
across
J2
and
the
AC
Voltmeter
across
J3.
5
Check
the
AC
Voltmeter
reading
is
between
0.7702
V
and
0.7791
V.
6
Connect
the
AC
Voltmeter
across
J2
and
the
resistor
across
J3
then
repeat
step
5.
7
Repeat
steps
2
to
6
with
the
Synthesizer
frequency
at
40
kHz.
F-
0
w
e:
r
s
i.„
r
■■
E
r
/
a
d
d
e
r
Replaceable
Parts
Ref.
Designator
Description
Qty.
HP
Part
No.
R1
to
R6
Resistor
Fxd
IOOQO.1%
1/8
W
6
0698-6323
JltoJ3
Connector
3-pin
3
1251-2533
MSC
Connector
single
pin
9
1251-0600
MSC
Blank
Printed
Circuit
Board
1
03779-20045
B-2
Service
Accessory
2
(SA2)
Power
Spiitter/Adder