EasyManua.ls Logo

HP 53131A/132A 225 MHz - Parameter Types

HP 53131A/132A 225 MHz
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Programming Your Universal Counter for Remote Operation
Elements of SCPI Commands
Programming Guide 3-11
Parameter Types
Table 3-1 contains explanations and examples of parameter types. Parameter
types may be numeric value, Boolean, literal, NRf, string, non-decimal numeric ,
or arbitrary block.
Table 3-1. Command and Query Parameter Types
TYPE EXPLANATIONS AND EXAMPLES
<numeric value>
<Boolean>
<literal>
<NRf>
<string>
<non-decimal
numeric>
<arbitrary block>
Accepts all commonly used decimal representation of numbers including optional signs, decimal
points, and scientific notation:
123, 123e2, -123, 1.23e2, .123, 1.23e 2, 1.23000E01.
Special cases include MINimum and MAXimum as follows:
MINimum selects minimum value available.
MAXimum selects maximum value available.
Queries using MINimum or MAXimum return the associated numeric value.
Represents a single binary condition that is either true or false:
1 or ON, 0 or OFF (Query response returns only 1 or 0.)
An <NRf> is rounded to an integer. A non-zero value is interpreted as 1.
Selects from a finite number of choices. These parameters use mnemonics to represent each valid
setting. An example is the INPut:COUPling AC | DC command parameters (AC | DC).
Flexible numeric representation. Only positive integers are used for NRf parameters in the Counter.
A string parameter is delimited by either single quotes or double quotes. Within the quotes, any
characters in the ASCII 7-bit code may be specified.
The following HP BASIC program statement sends a command containing a <string> parameter:
OUTPUT 703;"FUNC ‘FREQ’"
Format for specifying hexadecimal (#H1F), octal (#Q1077), and binary (#B10101011) numbers
using ASCII characters. May be used in :STATus subsystem commands.
The syntax is a pound sign (#) followed by a non-zero digit representing the number of digits in the
subsequent decimal integer. The decimal integer specifies the number of
8-bit data bytes being sent. This is followed by the actual data. The terminator is a line feed
asserted with EOI. For example, for transmitting 8 bytes of data, the format could be:
The 2indicates the number of digits that follow and the two digits 08indicate the number of data
bytes to be transmitted.
A zero-length block has the format: #0<new line>^EOI
<new line> is defined as a single ASCII-encoded byte corresponding to 10 decimal.

Table of Contents