29
Figure 25 Panel view of the 6000W AC
(1) Captive screws
(2) PoE power switch
(O for off, and | for on)
(3) Status LEDs (4) System power receptacle
(5) System power switch (O for off, and | for on)
(6) Holes for fixin
g
cable ties
(7) Power supply handle (8) PoE power receptacles
The power cord connection procedures are the same for the system power receptacle and PoE power
receptacle of the 6000W AC power supply. This section takes the system power receptacle for example.
To connect an AC power cord to the system power receptacle of the power supply:
1. Make sure of the power cord model (the 6000W AC power supply uses a 16A AC power cord).
2. Plug the power cord into the system power receptacle on the power supply, and ensure a good
contact.
3. As shown in Figure 26, secure the power cord to the power su
pply handle by using a cable tie.
4. Plug the other end of the power cord to the AC power receptacle of the power source.
5. Turn on the power switch.
6. Examine the power supply input status LED.
If the LED is green, the power cord is correctly connected. If the LED is off or red, examine the
installation, and solve the problem. Then switch on the power supply to verify that the LED is green.
For description of 6000W AC status LEDs, see "Appendix C LEDs."