port..
7. Verify that the speed and duplex settings of the ports of a link are the same. Make sure two ports
can work together.
CF card failure
The MPU provides a CFS LED. When the CF card operates correctly, the CFS LED is on.
If the CFS LED is off, the CFD card fails. To troubleshoot the CF card:
1. Verify that the MPU is operating correctly. For more information, see "MPU failure."
2. If the C
F card fails because you execute the umount command, you can execute the <Sysname>
mount cfa0: command in user view to re-mount the CF card.
3. Verify that the CF card is fully seated.
4. If you have a backup CF card, replace the current CF card with it to examine whether the current
CF card fails. For more information, see "Replacement procedures." After th
e replacement, if the
CFS LED is on, you can be sure that the previous CF card fails.
PoE system failure
If the switch cannot supply power for a PD attached to the switch, troubleshoot the PoE system, as follows:
1. Make sure you have set up the PoE system for the switch as follows: use the PoE-capable switch
and LPUs, use the PoE-capable power supply system, and configure the PoE dual-in-line memory
(DIMM) modules for LPUs except LSQ3GV48SC0 and LSQ1GV48SD0. For more information, see
"Installing FRUs."
2. Mak
e sure the PoE system can provide enough power for all attached PDs. For information about
the maximum PoE power consumption, see "Appendix A Chassis views and technical
specifi
cations."
3. Verify that the cable that connects the switch to the PD is a straight-through cable.
4. Make sure PoE-related configurations are correct. For how to configure PoE, see the related
configuration guide.