HP 7500 Series - Displaying the Operating Status of the Fan Assembly; Displaying the Operating Status of Power Supplies; Configuring the Temperature Thresholds for a Card

HP 7500 Series
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
Field Descri
p
tion
Status:
Operating status of the CF card:
Absent—No CF card is in the slot.
Fault—The CF card is faulty.
Normal—The CF card is correctly operating.
Size: Memory size of the CF card
Displaying the operating status of the fan assembly
Use the display fan command to display the operating status of the fan assembly:
<Sysname> display fan
Fan 1 State: Normal
Table 20 Command output
Field Remarks
Fan 1 Fan assembly number
State
Fan assembly status:
Normal—The fan assembly is correctly operating.
Absent—The fan assembly is absent.
Fault—The fan assembly has failed.
Displaying the operating status of power supplies
Use the display power command to display the operating status of power supplies:
<Sysname> display power
Power 1 State: Normal
Power 2 State: Absent
Table 21 Command output
Field Descri
p
tion
Power 1 Power supply number
State
Power supply status:
Normal—The power supply is correctly operating.
Absent—The power supply is absent.
Fault—The power supply has failed.
Configuring the temperature thresholds for a card
The switch sends traps when the temperature of a card crosses the lower or upper temperature threshold.
You can change the temperature threshold settings for a card as needed so you can remove the alarm
condition in time.
To configure and display the temperature thresholds for a card: