EasyManua.ls Logo

HP A7533A - Brocade 4Gb SAN Switch Base - Persistently enabling and disabling ports

HP A7533A - Brocade 4Gb SAN Switch Base
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fabric OS 5.x administrator guide 115
The command format is:
ficoncupset modereg [bitname] 0 | 1
The following example sets the mode register bit HCP to off:
The following example sets the mode register bit ACP to on:
Persistently enabling and disabling ports
When fmsmode is enabled, you cannot use the portCfgPersistentEnable and
portCfgPersistentDisable commands to persistently enable and disable ports. Instead, use this
procedure:
1. Issue the following command to display the mode register bit settings:
ficoncupshow modereg
2. Verify that the ASM bit is set on (1).
3. If the ASM bit is set off (0), issue the following command to set it on:
ficoncupset modereg asm 1
4. Use the portEnable and portDisable commands to enable and disable ports as necessary.
The ports remain enabled or disabled after a switch reboot.
In the following example, the ASM bit is set to on, and then the port at slot 1, port 1 is enabled
persistently:
where:
bitname Specifies one of the mode register bits described in Table 19 on page 114.
0 Specifies that the bit is off.
1 Specifies that the bit is on.
switch:admin> ficoncupset modereg HCP 0
Mode register bit HCP has been set to 0.
switch:admin> ficoncupset modereg ACP 1
Mode register bit ACP has been set to 1.
switch:admin> ficoncupshow modereg
POSC UAM ASM DCAM ACP HCP
------------------------------
1 0 0 0 1 1
switch:admin> ficoncupset modereg ASM 1
Mode register bit ASM has been set to 1.
switch:admin> portenable 1/1