Figure 6. HP BladeSystem c3000 Onboard Administrator link module 
 
 
 
Enclosure link cabling 
The Onboard Administrator link module contains two enclosure link ports to allow any active 
Onboard Administrator module to access linked enclosures. On a standalone enclosure or upper 
enclosure in a series of linked enclosures, the upper enclosure link-up port functions as a service port 
for temporary connection to a PC with a CAT5 patch cable. It provides quick access to any Onboard 
Administrator module, iLO 2, or interconnect module with Ethernet management ability.  
The enclosure link-down port connects to the enclosure link-up port on the enclosure below it. The 
enclosure link-up port connects to the enclosure link-down port on the enclosure above it. Linking the 
enclosures enables the rack technician to access all the enclosures through the open link-up/service 
port. If more c-Class enclosures are added to the rack, they can be linked through the open enclosure 
link-up port on the upper enclosure or the link-down port on the bottom enclosure. 
NOTE 
The enclosure link ports are designed only to support c-Class 
enclosures in the same rack. The enclosure link-down port on the 
upper enclosure is the service port. The enclosure link-down port 
on the bottom linked enclosure is unused. 
IMPORTANT 
The HP BladeSystem c-Class Enclosure link ports are not 
compatible with the HP BladeSystem p-Class Enclosure link 
ports. 
11