Scripted deployment 83
Parameter Description Possible values
values are case-sensitive
and must be capitalized
as shown. Failure to do
so prevents the trust
relationship from being
set up properly during
installation and might
affect access to the web
server.
CERTLIST
This parameter enables a user to provide a list of
certificate files or servers where certificates can
be obtained for trust relationships for the HP
Systems Management Homepage. (Applies to
Linux PSP only.)
Certificate file name or
Server DNS name
XENAMELIST
This parameter enables a user to provide a list of
servers, separated by semicolons, for trust
relationships for the HP Systems Management
Homepage. (Applies to Linux PSP only.)
This parameter is only valid if the TRUSTMODE
parameter is set to TrustByName. (Applies to
Linux PSP only.)
Server DNS name
HPQLA2X00FO
This parameter is used by the hp_qla2x00
QLogic Fibre Channel Driver to determine the
failover mode to use. (Applies to Linux PSP only.)
SinglePath
SecurePath
QLogicFailure
(No default value)
HPQLA2X00FORCE
This parameter is used by the hp_qla2x00
QLogic Fibre Channel Driver to determine
whether to skip detection of third-party storage.
(Applies to Linux PSP only.)
"Y", "N" (default)
OAUID
This parameter provides the username
credentials for OA associated with VC. You must
define a value of these variables before HOST
variable in [TARGETS] section. This parameter
only applies for VC firmware.
User can define OAUID
variable multiple times
before each HOST
variable.
OAPWD
This parameter provides the password
credentials for OA associated with VC. You must
define a value of these variables before HOST
variable in [TARGETS] section. This parameter
only applies for VC firmware.
User can define OAPWD
variable multiple times
before each HOST
variable.
Examples of the HP SUM input file include:
REBOOTALLOWED = YES
REBOOTREQUIRED = NO
REBOOTMESSAGE = "Server is going down for a reboot"
REBOOTDELAY = 15
COMPONENTSLIST = cp001234.exe, cp001235.exe
BUNDLESLIST = bp001234.xml

Table of Contents

Other manuals for HP Integrity rx2800 - i2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2800 - i2 and is the answer not in the manual?

HP Integrity rx2800 - i2 Specifications

General IconGeneral
Number of Processors1 or 2
Expansion Slots6 PCI-X slots
RAID SupportYes
Network ControllerIntegrated dual Gigabit Ethernet
Operating SystemsHP-UX, Linux, Windows Server
Form Factor2U rackmount
StorageUp to 1.8TB
NetworkEthernet