2-16
Installing the Switch
Installation Procedures
Installing the Switch
Flat Wall Mounting
You can mount the Non-PWR switches on a wall as shown in the illustration
on the next page. However, this is not supported for the 2626-PWR or the 2650-
PWR switches. Wall mounting the PWR switches is not supported because of
the size and weight of the devices. Wall mounting the 2600-8-PWR switch is
supported. See page 2-18 for instructions.
WARNING For safe operation do not install the switch with the back face of the
switch (with the fan vents) facing either downward or upward. Do not
wall mount the 2626-PWR or the 2650-PWR switches.
Caution The switch should be mounted only to a wall or wood surface that is at least
1/2-inch (12.7 mm) plywood or its equivalent.
Supported Wall Mounting Positions.
Switch Vertical Wall Mounting Horizontal Wall Mounting
2626 Non-PWR Yes No
2650 Non-PWR
Yes No
2626-PWR
No No
2650-PWR
No No
2600-8-PWR
No Yes