EasyManua.ls Logo

HP ProCurve 3500yl - Release K.11.44; Release K.11.46

HP ProCurve 3500yl
219 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
154
Software Fixes in Release K.11.12 - K.13.49
Release K.11.44
The following problems were resolved in release K.11.43 (not a general release)
Crash (PR_1000307842) — When deleting/removing CLI ACLs, IDM ACLs, management
VLAN, or virus throttle lockouts, switch crashes with error similar to:
"Delete virtual meter with nonzero rule RefCount".
Crash (PR_1000334982) — When Web authentication is used w ith op en VLAN s , a so ftwar e
exception may occur, with the switch reporting something similar to this.
Software exception at wma_vlan_sm.c:289 -- in 'mWebAuth',
task ID = 0x81e408e0 -> ASSERT: failed
Enhancement (PR_1000358903) — 802.1X Controlled Directions enhancement. With this
change, Administrators can use “Wake-on-LAN” with computers that are connected to ports
configured for 802.1X authentication.
VRRP (PR_1000356388) — VRRP returns the physical MAC address instead of the virtual
MAC address when replying with proxy-ARP.
Release K.11.44
The following problems were resolved in release K.11.44 (not a general release)
Enhancement (PR_1000361504) — This enhancement allows STP to detect and block
network topology loops on a single port.
Release K.11.46
Version K.11.45 was never released.
The following problems were resolved in release K.11.46 (not a general release)
CLI (PR_1000345301) — The output from the "show config state" CLI command doesn't
always report changes made to the configuration.
CLI (PR_1000305584) — The output from the "show power" commands on the ProCurve
3500yl switches references slot letters when it should display port numbers.
Crash (PR_1000357083) — The switch management may run out of packet buffers and
crash with a message similar to:
Software exception at ngDmaTx.c:722 -- in 'tDevPollTx', task ID = 0x4305c504 ->
HW DMA DRIVER unable.
Hang (PR_1000359640) — The switch may hang on initialization and become
unresponsive.

Table of Contents