EasyManua.ls Logo

HP ProCurve 3500yl - Release K.12.16; Release K.12.17

HP ProCurve 3500yl
219 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
168
Software Fixes in Release K.11.12 - K.13.49
Release K.12.16
Rate-Limiting (PR_1000420720) — Rate limiting is broken beyond 9.5 Mbps. For any rate
limit set to more than 9.5 Mbps, the actual rate drops to 1 Mbps.
Release K.12.16
The following problems were resolved in release K.12.16.
Crash (PR_1000415621) — Removing a VLAN that has OSPF configured may cause the
switch to crash with a message similar to:
NMI event HW:IP=0x0084a0a4 MSR:0x00029210 LR:0x00513ee4 Task='eRou-
teCtrl' Task ID=0x89658b0'
Crash (PR_1000428582) — Typing non-alphanumeric characters at the CLI prompt may
cause the switch to crash with a message similar to:
PPC Data Storage (Bus Error) exception vector 0x300:Stack
Frame=0x08e36878 HW Addr=0x00b4f2ec IP=0x0018a974 Task='mSess1' Task
ID=0x0fp: 0x18020800 sp:
Release K.12.17
The following problems were resolved in release K.12.17.
STP (PR_1000420442) — The switch erroneously allows configuration of spanning tree
parameters on an interface that is a member of a trunk (link aggregation group), which
creates an invalid configuration.
CLI (PR_1000429474) — The "all" parameter is missing from the "password" command.
Radius (PR_1000432556) — When DHCP snooping is enabled on the client VLAN, and the
client is on a VLAN other than the default VLAN, the Framed-IP-Address attribute is not added
to the RADIUS accounting packet as it should be.
Crash (PR_1000416453) — Execution of the "show tech" command in an SSH session may
cause the switch to crash with a message similar to:
Software exception - Assert in pmgr_util.c:1155 -- in 'mSess2', task
ID = 0x85adf60