D Specications
Unit Metric value Standard value
Chassis (in the desktop position)
Height
Width
Depth
95 mm
270 mm
300 mm
3.7 in
10.6 in
11.8 in
Approximate Weight 4.43 kg 9.8 lb
Weight Supported (maximum distributed load in desktop position) 35 kg 77 lb
Temperature Range
Operating
Nonoperating
10°C to 35°C
–30°C to 60°C
50°F to 95°F
–22°F to 140°F
NOTE: Operating temperature is derated 1.0°C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight.
Maximum rate of change is 10°C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10% to 90%
5% to 95%
10% to 90%
5% to 95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
5,000 m
15,240 m
16,404 ft
50,000 ft
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
Operating Line Frequency
90 VAC to 264 VAC
100 VAC to 240 VAC
50 Hz to 60 Hz
47 Hz to 63 Hz
Standard Eciency
High Eciency
180 W / 310 W active PFC
87/90/87 % ecient at 20/50/100% load (115 V)
Standard Eciency
High Eciency
250 W active PFC
90/92/89 % ecient at 20/50/100% load (115 V)
Rated Input Current 310 W / 4 A
250 W / 3 A
180 W / 2.3 A
1
This system uses an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use in
the countries of the European Union. The active power factor corrected power supply also has the added benet of not requiring an input