Removal and replacement procedures 44
5. Slightly pull up the battery holder from the chassis to access the battery cable connection underneath it,
and then disconnect the HP Smart Storage Battery cable.
6. Remove the HP Smart Storage Battery from its holder.
To replace the component, reverse the removal procedure.
FBWC module
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.