EasyManua.ls Logo

HP ProLiant DL380 G7 - DIMMs

HP ProLiant DL380 G7
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 70
8. Close and lock the heatsink retaining latches.
9. Install the air baffle ("Air baffle" on page 32).
10. If the PCI riser cage was removed, install the PCI riser cage.
11. Install the access panel ("Access panel" on page 31).
12. Install the server into the rack.
13. Power up the server.
DIMMs
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM identification (on page 97)."
To remove the component:
1. Power down the server (on page 26).
2. Extend or remove the server from the rack ("Remove the server from the rack" on page 28, "Extend the
server from the rack" on page 27).
3. Remove the access panel ("Access panel" on page 31).
4. Remove the air baffle ("Air baffle" on page 32).

Table of Contents

Other manuals for HP ProLiant DL380 G7

Related product manuals