Removal and replacement procedures 39
7.
Remove the non-hot-plug drive backplane.
To replace the component, reverse the removal procedure.
Four-bay LFF hot-plug drive backplane
To remove the component:
1. Power down the server (on page 27).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend or remove ("Remove the server from the rack" on page 30) the server from the rack.
4. Remove the access panel ("Access panel" on page 37).
5. Remove all hot-plug hard drives ("Hot-plug drive" on page 36).
6. Disconnect all cables connected to the drive backplane.
7. Remove the hot-plug drive backplane.