Removal and replacement procedures 44
a.
Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 27).
o Remove the server from the rack (on page 30).
4. Remove the access panel ("Access panel" on page 37).
5. If installed, remove any expansion board that blocks access to the SSD module ("Expansion board"
on page 58).
6. Remove the SSD module.
To replace the component, reverse the removal procedure.
Optical drive blank
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power
input modules, and the internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
To remove the component:
1. If installed, remove the security bezel ("Remove the security bezel (optional)" on page 26).
2. Power down the server (on page 27).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o Extend the server from the rack (on page 27).
o Remove the server from the rack (on page 30).
5. Remove the access panel ("Access panel" on page 37).