NOTE: Not all of the options in this table are adjustable on all servers. However, even if you do
not have the option of adjusting some of these settings, they will default to the values shown here.
Quick Configs settings (Intel-based servers)
Power management options
Maximum performanceMinimum power usageBalanced power and
performance
Maximum PerformanceMinimum Power UsageBalanced Power and
Performance
HP Power Profile
HP Static High Performance
Mode
HP Static Low Power ModeHP Dynamic Power Savings
Mode
HP Power Regulator
DisabledEnabledEnabledIntel QPI Link Power
Management
No C-statesC6 StateC6 StateMinimum Processor Idle
Power Core State
No Package StatePackage C6 (retention) StatePackage C6 (retention) StateMinimum Processor Idle
Power Package State
Maximum PerformancePower Savings ModeBalanced PerformanceEnergy/Performance Bias
Auto1333 MHzAutoMaximum Memory Bus
Frequency
EnabledDisabledEnabledChannel Interleaving
Maximum SupportedPCIe Generation 1Maximum SupportedMaximum PCI Express
Speed
AutoMinimum QPI SpeedAutoIntel QPI Frequency
Using iLO Configuration Utility
Use the iLO Configuration Utility to view and change iLO settings through Intelligent Provisioning,
instead of through the iLO web interface. For more information about iLO, see the HP iLO 4 User
Guide.
You must configure iLO network settings to register the server with the HP Insight Remote Support
registration process.
When changing iLO settings, if the display is not as expected or an undefined error message is
displayed, press F5 to refresh the screen display. It is possible that the change was being made
at the same time through the iLO web interface.
To use iLO Configuration Utility:
1. On the Intelligent Provisioning home screen, click Perform Maintenance.
2. Select iLO Configuration from the maintenance options.
The iLO Configuration Utility window is displayed.
Viewing iLO summary information
To view iLO summary information:
Using iLO Configuration Utility 49