Removal and replacement procedures 56
2.
Remove the heatsink protective cover.
3. Install the heatsink, and then close the heatsink retaining levers.
4. Install the air baffle.
5. Install the access panel.
6. Do one of the following:
o For tower models, return the server to an upright position, and then install the bezel.
o For rack models, slide the server back into the rack.
7. Connect each power cord to the server.
8. Connect each power cord to the power source.
9. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.

Table of Contents

Other manuals for HP ProLiant ML350p Gen8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML350p Gen8 and is the answer not in the manual?

HP ProLiant ML350p Gen8 Specifications

General IconGeneral
ProcessorIntel Xeon E5-2600 series
Maximum Processors2
ChipsetIntel C600 Series
Memory TypeDDR3 RDIMM or UDIMM
Maximum Memory768 GB
Memory Slots24 DIMM slots
RAID SupportHP Smart Array P420i/1GB FBWC
Storage ControllerHP Smart Array P420i/1GB FBWC
Network ControllerHP Ethernet 1Gb 4-port 331FLR Adapter
Form FactorTower
StorageSAS, SATA, SSD
NetworkGigabit Ethernet
Power Supply460W, 750W, 1200W
Power Supply OptionsRedundant Power Supplies
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware