Details the features and board components of the HP Smart Array P400 controller, including runtime LEDs.
Details the features and board components of the HP Smart Array P411 controller, including runtime LEDs.
Details the features and board components of the HP Smart Array P700m controller, including runtime LEDs.
Details the features and board components of the HP Smart Array P711m controller, including its runtime LED.
Details the features and board components of the HP Smart Array P800 controller, including runtime LEDs.
Details the features and board components of the HP Smart Array P812 controller, including runtime LEDs.
Explains how physical disk failures affect logical drives based on configured RAID levels.
Provides guidance on selecting the best RAID method based on needs, comparing different RAID levels.
Details how to verify and update the controller firmware version offline using the saupdate utility.
Details how to confirm and update firmware versions on physical disks attached to the Smart Array Controller.
Describes the steps to enable system booting from logical drives configured on a Smart Array Controller.
Guides users through determining RAID levels, disk configurations, and stripe sizes for RAID setup.
Explains how to use the saconfig command-line interface for configuring Smart Array SAS Controllers.
Details how to create, view, and delete logical drives using the ORCA utility before loading an OS.
Provides the command syntax and parameters for configuring a logical drive using saconfig.
Explains how to delete a logical drive using the saconfig command, with warnings about data loss.
Explains how to migrate an existing logical drive to a different RAID level using the saconfig command.
Describes how to extend a logical drive's capacity by adding storage space from existing physical disks.
Focuses on sautil command options for online troubleshooting of HP Smart Array Controllers.
Details how to confirm and update the firmware version installed on the Smart Array Controller using sautil.
Explains how to confirm and update firmware for SAS storage enclosures attached to the Smart Array controller.
Provides the syntax for updating the firmware of a SAS storage enclosure using the sautil command.
Details how to use the sautil command to confirm physical disk failures and check logical drive status.
Explains situations where fault tolerance is compromised due to multiple disk failures or other issues.
Discusses the procedure for replacing physical disks, including hot-pluggable disks.
Explains the controller's process for rebuilding data onto a replacement disk after a failure.
Provides detailed specifications for the HP Smart Array P400 controller.
Provides detailed specifications for the HP Smart Array P411 controller.