Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0J4A000009748XQZG
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. INIT RESET RECOVERY ABORTED
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 1E:1:4:0x5000c500052d5175 [DISK] ------------------------
Connector Location............................... external
Connector........................................ 1E
Enclosure........................................ 1
Bay.............................................. 4
WWID............................................. 0x5000c500052d5175
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0H0E700009748WS5P
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. INIT RESET RECOVERY ABORTED
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 1E:1:0:0x50001c1071540025 [SES] -------------------------
The sautil command 73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Smart Array HP-UX 11i v2 and is the answer not in the manual?

HP Smart Array HP-UX 11i v2 Specifications

General IconGeneral
BrandHP
ModelSmart Array HP-UX 11i v2
CategoryServer
LanguageEnglish

Related product manuals