Connector Location............................... external
Connector........................................ 1E
Enclosure........................................ 1
Bay.............................................. 0
WWID............................................. 0x50001c1071540025
Device Type...................................... SES
Disk Capacity.................................... 0.0 GB
Device Status.................................... FAILED
Device Vendor ID................................. HP
Device Product ID................................ MSA70
Device Serial Number............................. SGA728007J
Device Firmware Version.......................... 1.42
Reserved Area (cfg/status info).................. 0.0 KB (0.0 MB)
Block Size (bytes/sector)........................ 0 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. NON DISK DEVICE
Physical Disk Flags:
Disk present and operational................... no
Non-disk device detected....................... yes
S.M.A.R.T. supported........................... no
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. no
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. no
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... no
---- SAS/SATA DEVICE 2E:1:0:0x5001438000328825 [SES] -------------------------
Connector Location............................... external
Connector........................................ 2E
Enclosure........................................ 1
Bay.............................................. 0
WWID............................................. 0x5001438000328825
Device Type...................................... SES
Disk Capacity.................................... 0.0 GB
Device Status.................................... FAILED
Device Vendor ID................................. HP
Device Product ID................................ MSA70
Device Serial Number............................. SGA72800DF
Device Firmware Version.......................... 1.50
Reserved Area (cfg/status info).................. 0.0 KB (0.0 MB)
Block Size (bytes/sector)........................ 0 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. NON DISK DEVICE
Physical Disk Flags:
Disk present and operational................... no
Non-disk device detected....................... yes
S.M.A.R.T. supported........................... no
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. no
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. no
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
74 Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Smart Array HP-UX 11i v2 and is the answer not in the manual?

HP Smart Array HP-UX 11i v2 Specifications

General IconGeneral
BrandHP
ModelSmart Array HP-UX 11i v2
CategoryServer
LanguageEnglish

Related product manuals