4 Storage Configuration
This section describes how to configure the storage after the nodes have been configured.
Establishing Communication Between the VLS12000 Gateway
and the EVA
Verifying Array Zoning
Verify that you have configured the zoning between the EVA ports and all storage ports on all the
nodes of your VLS Gateway. For example, storage ports 2 and 3 on each node should connect to
different SAN zones/fabrics; EVA controllers should also be connected to both zones/fabrics. If you
have not done so, refer to the HP StorageWorks VLS and D2D Solutions Guide to do so now.
Presenting the LUNs
NOTE:
If you have noted the list of WWPNs while performing the multi-node setup (see
Configuring the Secondary Nodes 1 through 7 on page 33), go directly to step 2 of the procedure
below.