Table 40 Warning event codes (continued)
Details and SolutionDescriptionEvent code
DHCP request has failed85
• Check the network to ensure connection to
the DHCP server.
• Check that the network configuration is correct.
• If DHCP is enabled, ensure that the DHCP
server is up and running on the device's
network.
• Power cycle the device and retry the operation.
Insert a valid cleaning cartridge into the library.Autoclean media warning; not enough media
present to support autocleaning.
86
Replace the drive with a compatible tape drive.Drive not supported; the tape drive was disabled
because it cannot be used in this library.
87
Drive firmware revision has not changed after
a tape drive firmware upgrade.
88
• Verify that the firmware image is correct for
the tape drive.
• Retry the operation.
• Retry using an alternate firmware upgrade
method.
Power supply fan has failed. Redundancy may
be at risk.
89
• Verify that the indicated fan is operational and
not physically obstructed.
• Upgrade to the latest version of firmware.
NOTE: The sub-error code indicates the
affected power supply. 00 is the bottom power
supply. 01 is the second power supply.
Power supply has failed. Redundancy is not
available.
8A
• Check the AC power cable connection.
• Verify that the indicated power supply is
correctly installed and the thumbscrews are
tight.
NOTE: The sub-error code indicates the
affected power supply. 00 is the bottom power
supply. 01 is the second power supply.
One of the redundant power supplies has failed.8B
• Check the AC power cable connections.
• Verify that both power supplies are correctly
installed and the thumbscrews are tight.
Install new library firmware, which will install a
compatible robotics firmware version.
Invalid robotics code; does not match with the
loaded library firmware.
8C
Obtain a new cleaning tape for use when the
current cleaning tape expires.
Cleaning tape nearly expired. Only one or two
cleaning operations remain.
8E
Contact Hewlett Packard Enterprise Service if
this unexpected condition occurs.
I
2
C bus recovery8F
Power supply has failed. Master library power
redundancy not available.
90
• Verify that both power supplies are correctly
installed and the thumbscrews are tight.
Power supply has failed. Lower library power
redundancy not available.
91
• Check AC power cable connections
NOTE: The MSL2024 does not have a
redundant power supply option.
Power cycle the device and retry the operation.VPD data recovery.92
Warning events 179