# hardware show status 50014380254FAD32
Name Dev-id Status
----------------------- ---------------------- --------
- 50014380254FAD32 DEGRADED
Disk 5000C50055C1BB0B 5000C50055C1BB0B OK
- Drive_Missing_b1000103 FAILED
3. When you reach the faulty component, use the following command to display details and look at the
diagnostic message for more information.
hardware show status <Dev-id> details
For example:
# hardware show status 50014380254FAD32 details
Name
----------------------------------------------
-
Dev-id = 50014380254FAD32
Status = DEGRADED
message = -
type = driveEnclosure
model = ServBP 4
serialNumber = -
firmwareVersion = -
location = -
Disk 5000C50055C1BB0B
Dev-id = 5000C50055C1BB0B
Status = OK
message = -
type = drive
model = MM1000FBFVR
serialNumber = 9XG3601K00009316ZLN0
firmwareVersion = HPD8
location = Port: 1I Box: 2 Bay: 1
volumeName = LUN 1
capacity = 1.00 TB
-
Dev-id = Drive_Missing_b1000103
Status = FAILED
message = The drive has failed.
type = drive
model = -
serialNumber = -
firmwareVersion = -
location = Port: 1I Box: 2 Bay: 2
volumeName = LUN 1
capacity = 1.00 TB
4. After identifying the issue that needs to be corrected, follow the instructions in the relevant chapter of
this guide.
5. Verify that all problems have been resolved. Rerun the StoreOnce CLI command:
24 Identifying problems