Figure 27: Removing the AC power cooling module
Replacement
11. Install the AC PCM.
a. On the ESD mat, extend the PCM handle to the open position, and then carry it to the enclosure.
b. Slide the PCM into the enclosure and then push until the insertion mechanism starts to engage
(the handle starts to rotate).
Ensure that no cables get caught in the PCM insertion mechanism.
c. Close the handle until the latch clicks to fully seat the PCM in the enclosure.
d. Once inserted, pull back lightly on the PCM to ensure that it is properly engaged.
Figure 28: Installing the AC power cooling module
12. Connect the power cable and turn on the power to the AC PCM.
a. Reconnect the power cable.
b. Slide the cable clamp onto the cable tie.
Service 35