24
Connecting a PSR720-56A (JG544A)/PSR1110-56A
(JG545A)/PSR150-A (JD362A)/PSR150-A1 (JD362B) power
supply
The procedure is similar for connecting a PSR720-56A (JG544A), PSR1110-56A (JG545A), or
PSR150-A/PSR150-A1 (JD362A/JD362B) power supply. The following uses the PSR720-56A
(JG544A) power supply as an example.
To connect a PSR720-56A (JG544A) power supply:
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Plug the female connector end of the AC power cord into the AC input socket of the power
supply (see callout 1 in Figure 30).
3. Use a cable tie to secure the power cord to the handle of the power supply (see callout 2 and
callout 3 in Figure 30).
4. Connect the other end of the AC power cord to an AC power outlet.
Figure 30 Connecting a PSR720-56A (JG544A) power supply
Installing/removing an interface card
CAUTION:
• Do not touch the surface-mounted components on an interface card directly with your hands.
• Do not use excessive force during the installation or removal procedure.
• Install a filler panel over an empty interface card slot.
The switch has an interface card slot and supports hot swapping of an interface card. For the
interface cards available for the switches, see "Appendix B FRUs and compatibility matrixes."